Friction Loss Equations for Hydropower Facilities
Many water suppliers are pursuing economic benefits from water supply and distribution systems through development of hydropower facilities on pipelines. Excessive pressure head that used...

Hydraulic Modeling of High Unit Discharge Energy Dissipators
The incorporation of an efficient and economical energy dissipation device is critical with respect to the safe operation of a high unit discharge spillway. The development and design...

Determination of Pulsating Pressures for Baldhill Dam, N.D. Spillway
Model tests of the existing Baldhill Spillway were conducted with symmetrical and asymmetrical gate openings to determine for various flow conditions the characteristics of the hydraulic...

Interaction of Steel Structure and Composite Supercolumns in Spine Structures
Modern architecture has departed from uniform rectangular cigarette boxes for high-rise buildings. A structural system which goes uninterrupted through the common denominator of the varying...

Cyclic Lateral Load Analysis of Composite Frames
A method of analysis for composite building frames subjected to repeated and reversed lateral loads has been developed as part of an overall investigation of seismic response of composite...

Proposal on Story Drift Limit Based on Axial Behavior of Column under Seismic Loads
The main function of columns primarily is to support axial loads both under and after repeated lateral loading from earthquakes. A definition of the story drift limit in any structural...

Sliplining: Design and Installation Considerations for Polyethylene Pipe
The design methodology and installation procedure for polyethylene slipline renewal are discussed. When designing there are two critical phases which must be considered: (1) short-term...

Structural Design on Ductile Iron Pipe
The thickness class designation for Ductile Iron pipe has been changed to a pressure class designation in the 1991 revision of the C150/A21.50 ANSI standard. However, the same conservative...

Reinforced and Prestressed Concrete Pressure Pipe Diagnosis
Prestressed and reinforced concrete steel cylinder pipes are used for transmission mains, water intake lines, sewers force mains. Many collapses caused by the steel cylinder attack were...

Selection and use of Pipeline Leak Detection Methods for Liability Management into the 21st Century
Pipeline leak detection systems have been in use for many years on all types of pipelines with various products being transported. Pipeline owners and operators are subject to stringent...

Relocating a 54-Inch Diameter Force Main without Interrupting Wastewater Flow
The City of Tampa, Florida, was faced with the challenge of relocating three segments of an old 1372 mm (54-in.) diameter reinforced concrete pipe force main, totaling nearly a mile in...

The Load Factor
Spangler's load-factor formula for projecting conduits is generalized to all cases of buried rigid pipe, whether in trenches or under embankments; this is in accordance with the analytical...

Lateral Loading Curves from Pressuremeter Tests
The large drilled shafts for the proposed Klamath Falls Bridge, which are to be founded in diatomaceous silts, were to be designed to withstand earthquake induced large cyclic loading....

Evaluation of Dilatometer Method to Determine Axial Capacity of Driven Model Pipe Piles in Clay
The flat Dilatometer (DMT) provides a unique approach to estimate the effective stress axial capacity of driven displacement piles in clay. An investigation using this approach was performed...

Behavior of Suction Piles in Sand
In the marine environment, use of suction pressure for the installation of sealed top piles (suction piles) is a promising alternative to driven pile foundations, particularly in deep...

Load Testing of Permanently Cased Drilled Shafts Founded in Hartford Shale
The axial and lateral load testing of three, 30 inch (76cm) diameter, permanently cased drilled shafts is analyzed herein. The prototype shafts were founded in (or on) Hartford Shale bedrock,...

Transmitted Swelling Pressures on Retaining Structures
The main objectives of this paper are to describe a finite element model to simulate the lateral swelling behavior of expansive soils as a function of soil suction change in the soil domain...

Elasto-Plastic Volume Change of Unsaturated Compacted Clay
Isotropic compression tests were performed on samples of unsaturated compacted kaolin in a modified triaxial cell that allowed separate control of pore water pressure and pore air pressure....

One and Three Dimensional, Three Phase Deformation in Soil
An initially saturated soil exhibits two distinct deformation patterns as it drys. First, it deforms vertically until the soil begins to drain. Secondly , it deforms laterally as well...

Slip-Lining Solution
Grouting the annular space between a corroded sewer pipe and newly installed liner pipe is a stage of a typical sewer line rehabilitation project which contains hidden problems and difficulties....

 

 

 

 

Return to search